  • E2R316WA12U49
    $15,888.00

    E2R316WA12U49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC. A12 Option Includes: [2-A (Open) 2-B(Closed) Auxiliary Switch Installed, Right Pole Mounted, Exiting Right], U49 Option Includes: [110-127 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration A12 Option Includes: [2-A (Open) 2-B(Closed) Auxiliary Switch Installed, Right Pole Mounted, Exiting Right], U49 Option Includes: [110-127 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T33WA12U49
    $9,995.00

    E2R316T33WA12U49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC, A12 Option Includes: [2A-2B Auxiliary, Right Pole Mounted, Exiting Right], U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration A12 Option Includes: [2A-2B Auxiliary, Right Pole Mounted, Exiting Right], U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R320T33W
    $9,095.00

    E2R320T33W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 2000 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 2000 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R320T32W
    $9,095.00

    E2R320T32W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 2000 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 2000 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R320T33WA12U49
    $9,995.00

    E2R320T33WA12U49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 2000 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC, A12 Option Includes: [2-A (Open) 2-B(Closed) Auxiliary Switch Installed, Right Pole Mounted, Exiting Right], U49 Option Includes: [110-127 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration A12 Option Includes: [2-A (Open) 2-B(Closed) Auxiliary Switch Installed, Right Pole Mounted, Exiting Right], U49 Option Includes: [110-127 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 2000 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM320T33W
    $11,095.00

    E2RM320T33W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 2000 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 2000 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM320T32W
    $11,095.00

    E2RM320T32W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 2000 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 2000 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T32WA12S29
    $11,995.00

    E2RM316T32WA12S29

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC, A12 Option Includes: [2-A (Open) 2-B (Closed) Auxiliary Switch Installed, Right Pole Mounted, Exiting Right], S29 Option Includes: [110-240 VAC Shunt Trip Installed, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration A12 Option Includes: [2-A (Open) 2-B (Closed) Auxiliary Switch Installed, Right Pole Mounted, Exiting Right], S29 Option Includes: [110-240 VAC Shunt Trip Installed, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T33WU49
    $11,695.00

    E2RM316T33WU49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC, U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specification Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T33WU57
    $11,695.00

    E2RM316T33WU57

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC, U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T33W
    $11,095.00

    E2RM316T33W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T32WU57
    $11,695.00

    E2RM316T32WU57

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC, U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T32WU49
    $11,695.00

    E2RM316T32WU49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC, U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T33W
    $9,095.00

    E2R316T33W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T33WU57
    $9,695.00

    E2R316T33WU57

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Function, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC, U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T33WU49
    $9,695.00

    E2R316T33WU49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LS Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC, U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T32WU57
    $10,095.00

    E2R316T32WU57

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC, U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U57 Option Includes: [380-500 VAC UVR Installed, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T32WU49
    $10,095.00

    E2R316T32WU49

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Funtions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC, U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Configuration U49 Option Includes: [110-127 VAC UVR, Non LED, Right Pole Mounted, Exiting Right] Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2RM316T32W
    $11,095.00

    E2RM316T32W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2RM Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 1000VAC @ 50/60HZ, Interrupting Ratings: 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 1000 Interrupting Capacity Rating 65 Kiloampere @ 480 VAC, 50 Kiloampere @ 600 VAC, 25 Kiloampere @ 1000 VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun
  • E2R316T32W
    $9,495.00

    E2R316T32W

    Eaton / Cutler Hammer
    Delivery
    Free with $500 Order
    Get it by Tue, 10 Jun
    Product Description Specs are as follows: E2R Frame Style, Molded Case Mining Circuit Breaker, Non-Interchangeable Electronic Trip Unit, LSI Trip Unit Functions, 1600 Ampere Max at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC. ATTENTION: This unit requires a rating plug in order to function. Please contact us to check stock and pricing of rating plugs if you need one installed before ordering. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Eaton / Cutler Hammer Warranty One Year Connection Bolt On Frame Type R Amperage 1600 Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 125 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 50 Kiloampere @ 600VAC Trip Setting 2-8 Times the Continuous Ampere Rating Standard Lug Type
    Delivery
    Free with $500 Order
    Get it byTue, 10 Jun