NCGA31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCGA Frame Style, Frame Only, Molded Case Circuit Breaker, LSIG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Bolt On Frame Type NCGA Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $4,495.00- $29,995.00
NCG31200F w/600A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCG Frame Style, Molded Case Circuit Breaker, LSG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC , 600A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse / Cutler-Hammer Warranty One Year Configuration 12NC600 Frame Type NC Amperage 600 Poles 3 Voltage Max 600 Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 1,200-4,800 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $4,395.00- $29,995.00
NCG31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCG Frame Style, Frame Only, Molded Case Circuit Breaker, LSG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC , No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse / Cutler-Hammer Warranty One Year Frame Type NC Amperage 1200A Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $3,995.00- $29,995.00
NCA31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCA Frame Style, Molded Case Circuit Breaker, LSI Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Frame Type NCA Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $3,395.00- $29,995.00
NC31200FM (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NC Frame Style, Frame Only, Molded Case Circuit Breaker, Mag Only Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC , No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Bolt On Frame Type NC Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $3,495.00- $29,995.00
NC31200F w/600A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NC Frame Style, Molded Case Circuit Breaker, LS Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC , 600A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC600 Connection Bolt On Frame Type NC Amperage 600 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 1,200-4,800 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $3,495.00- $29,995.00
NC31200FM w/600A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NC Frame Style, Molded Case Circuit Breaker, Mag Only Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC , 600A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC600 Connection Bolt On Frame Type NC Amperage 600 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 1,200-4,800 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $3,395.00- $29,995.00
NC31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NC Frame Style, Frame Only, Molded Case Circuit Breaker, LS Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC , No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Bolt On Frame Type NC Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,895.00- $44,495.00
HNCGA31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCGA Frame Style, Molded Case Circuit Breaker, Mark 75, LSIG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Bolt On Frame Type HNC Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,350.00- $44,495.00
HNCG31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCG Frame Style, Molded Case Circuit Breaker, Mark 75, LSG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse / Cutler-Hammer Warranty One Year Frame Type NC Amperage 1200A Max Poles 3 Voltage Max 600 Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,450.00- $44,495.00
HNCG31200F w/600A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCG Frame Style, Molded Case Circuit Breaker, Mark 75, LSG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 600A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse / Cutler-Hammer Warranty One Year Configuration 12NC600 Frame Type NC Amperage 600 Poles 3 Voltage Max 600 Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 1,200-4,800 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $5,895.00- $44,495.00
HNCA31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCA Frame Style, Frame Only, Molded Case Circuit Breaker, Mark 75, LSI Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Bolt On Frame Type HNCA Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $5,495.00- $44,495.00
HNC31200FM w/1200A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNC Frame Style, Molded Case Circuit Breaker, Mag Only Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 1200A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1200 Connection Frame Type HNC Amperage 1200 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 2,400-9,600 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $5,395.00- $44,495.00
HNC31200FM (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNC Frame Style, Frame Only, Molded Case Circuit Breaker, Mag Only Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Connection Frame Type HNC Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $5,395.00- $44,495.00
HNC31200F (Frame Only)
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNC Frame Style, Frame Only, Molded Case Circuit Breaker, LS Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, No Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1200 Connection Frame Type HNC Amperage 1200A Max Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $5,495.00- $44,495.00
HNC31200F w/1200A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNC Frame Style, Molded Case Circuit Breaker, LS Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 1200A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1200 Connection Frame Type HNC Amperage 1200 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 2400-9600 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,995.00- $44,495.00
HNCGA31200F w/1200A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCGA Frame Style, Molded Case Circuit Breaker, Mark 75, LSIG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 1200A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1200 Connection Bolt On Frame Type HNC Amperage 1200 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 2400-9600 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,995.00- $44,495.00
HNCGA31200F w/1000A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCGA Frame Style, Molded Case Circuit Breaker, Mark 75, LSIG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 1000A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1000 Connection Bolt On Frame Type HNC Amperage 1000 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 2000-8000 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,995.00- $44,495.00
HNCGA31200F w/900A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCGA Frame Style, Molded Case Circuit Breaker, Mark 75, LSIG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 900A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC900 Connection Bolt On Frame Type HNC Amperage 900 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 1,800-7,200 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $6,995.00- $44,495.00
HNCGA31200F w/600A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: HNCGA Frame Style, Molded Case Circuit Breaker, Mark 75, LSIG Function Non-Interchangeable Trip Unit, High Interrupting Capacity, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Style, Interrupting Ratings: 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC, 600A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC600 Connection Bolt On Frame Type HNC Amperage 600 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 65 Kiloampere @ 240VAC, 50 Kiloampere @ 480VAC, 25 Kiloampere @ 600VAC Trip Setting 1,200-4,800 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $4,995.00- $29,995.00
NCGA31200F w/1200A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCGA Frame Style, Molded Case Circuit Breaker, LSIG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC, 1200A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1200 Connection Bolt On Frame Type NCGA Amperage 1200 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 2400-9600 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $4,995.00- $29,995.00
NCGA31200F w/1000A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCGA Frame Style, Molded Case Circuit Breaker, LSIG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC, 1000A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC1000 Connection Bolt On Frame Type NCGA Amperage 1000 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 2000-8000 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $4,995.00- $29,995.00
NCGA31200F w/900A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCGA Frame Style, Molded Case Circuit Breaker, LSIG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC, 900A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC900 Connection Bolt On Frame Type NCGA Amperage 900 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 1800-7200 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr - $4,995.00- $29,995.00
NCGA31200F w/600A Rating Plug
WestinghouseNo reviewsFree Store PickupMon, 28 Apr atDeliveryFree with $500 OrderGet it by Mon, 28 AprProduct Description Specs are as follows: NCGA Frame Style, Molded Case Circuit Breaker, LSIG Function Non-Interchangeable Trip Unit, 3 Pole, 600VAC @ 50/60HZ, Interrupting Ratings: 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC, 600A Rating Plug Installed, 1200A Maximum Frame Size, Without Terminals Standard. L – Adjustable Long Delay Pickup (By Adjustable Rating Plug) S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) or Adjustable Short Time (Flat Response) I – Adjustable Instantaneous Pickup by Setting Short Time Delay Time to Instantaneous G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) This product image represents a base model and is for identification purposes only. Are you purchasing accessories and your breaker in the same order? We will install your accessories to meet your specific configuration needs at NO ADDITIONAL COST! Just provide the necessary information in the order comment box during checkout. Specifications Manufacturer Westinghouse Warranty One Year Configuration 12NC600 Connection Bolt On Frame Type NCGA Amperage 600 Poles 3 Voltage Max 600 VAC Interrupting Capacity Rating 42 Kiloampere @ 240VAC, 30 Kiloampere @ 480VAC, 22 Kiloampere @ 600VAC Trip Setting 1200-4800 Standard Lug Type Without Terminals StandardFree Store ddPickupMon, 28 Apr atDeliveryFree with $500 OrderGet it byMon, 28 Apr
Let customers speak for us
from 168 reviewsvery fast and efficient
I ordered 9 starter switches and they were next day delivery. Installed and worked great. I am in the process of ordering spare ones now. Definitely recommend
Had to replace an older starter. Communication with the company was easy and accurate. Customer service worked with me to ensure the order was correct and shipped on time. Highly recommend reaching out with any questions, great company.
CHND312T33W
Great service, exactly what I ordered, thanks
QUICK SERVICE, EXCELLENT PRODUCT. CUSTOMER IS VERY HAPPY !
Excellent service very happy with the product
PAF361000
QUICK. SMOOTH. AND EASY. THANK YOU
Received Breaker quick and works great. We will do business together
Refurbished breaker, shipped quickly, worked perfectly, saved over $2,000 over the cost of a new breaker!
Win, win, win. you made money, I made money, and my client was elated to find the item.
Thanks
Great to work with, fast and efficient delivery. I Look forward to working with you again. Thank you!
FD3225L
The new surplus THJK436225 arrived in perfect condition just as it was described. Professionally packaged in pristine condition. Couldn't ask for more.